power: supply: cw2015: correct time_to_empty units in sysfs
RRT_ALRT register holds remaining battery time in minutes therefore it
needs to be scaled accordingly when exposing TIME_TO_EMPTY via sysfs
expressed in seconds
Fixes: b4c7715c10 ("power: supply: add CellWise cw2015 fuel gauge driver")
Signed-off-by: Jan Palus <jpalus@fastmail.com>
Link: https://lore.kernel.org/r/20231111221704.5579-1-jpalus@fastmail.com
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
b85ea95d08
commit
f376691194
|
|
@ -491,7 +491,7 @@ static int cw_battery_get_property(struct power_supply *psy,
|
|||
|
||||
case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
|
||||
if (cw_battery_valid_time_to_empty(cw_bat))
|
||||
val->intval = cw_bat->time_to_empty;
|
||||
val->intval = cw_bat->time_to_empty * 60;
|
||||
else
|
||||
val->intval = 0;
|
||||
break;
|
||||
|
|
|
|||