ASoC: codecs: wsa884x: report temps to hwmon in millidegree of Celsius

Temperatures are reported in units of Celsius however hwmon expects
values to be in millidegree of Celsius. Userspace tools observe values
close to zero and report it as "Not available" or incorrect values like
0C or 1C. Add a simple conversion to fix that.

Before the change:

wsa884x-virtual-0
Adapter: Virtual device
temp1:         +0.0°C
--
wsa884x-virtual-0
Adapter: Virtual device
temp1:         +0.0°C

Also reported as N/A before first amplifier power on.

After this change and initial wsa884x power on:

wsa884x-virtual-0
Adapter: Virtual device
temp1:        +39.0°C
--
wsa884x-virtual-0
Adapter: Virtual device
temp1:        +37.0°C

Tested on sm8550 only.

Cc: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Cc: Srinivas Kandagatla <srinivas.kandagatla@linaro.org>
Signed-off-by: Alexey Klimov <alexey.klimov@linaro.org>
Link: https://patch.msgid.link/20250221044024.1207921-1-alexey.klimov@linaro.org
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Alexey Klimov 2025-02-21 04:40:24 +00:00 committed by Mark Brown
parent 4363f02a39
commit d776f016d2
No known key found for this signature in database
GPG Key ID: 24D68B725D5487D0

View File

@ -1875,7 +1875,7 @@ static int wsa884x_get_temp(struct wsa884x_priv *wsa884x, long *temp)
* Reading temperature is possible only when Power Amplifier is
* off. Report last cached data.
*/
*temp = wsa884x->temperature;
*temp = wsa884x->temperature * 1000;
return 0;
}
@ -1934,7 +1934,7 @@ static int wsa884x_get_temp(struct wsa884x_priv *wsa884x, long *temp)
if ((val > WSA884X_LOW_TEMP_THRESHOLD) &&
(val < WSA884X_HIGH_TEMP_THRESHOLD)) {
wsa884x->temperature = val;
*temp = val;
*temp = val * 1000;
ret = 0;
} else {
ret = -EAGAIN;