From c774a623c821a173c950e1297f8e8c85a89455be Mon Sep 17 00:00:00 2001 From: Henrik Grimler Date: Tue, 11 Aug 2026 13:47:45 +0200 Subject: [PATCH] power: supply: bq27xxx: bq27520g4: fix REG_TTES address According to the technical reference manual the StandbyTimeToEmpty (TTES) register is at 0x1a, not 0x1c. At 0x1c StateOfHealth instead resides. Fixes: 8835cae5f2ab ("power: supply: bq27xxx: adds specific support for bq27520-g4 revision.") Signed-off-by: Henrik Grimler Link: https://patch.msgid.link/20260811-bq27z746-v1-3-3a4fa38205cc@axis.com Signed-off-by: Sebastian Reichel --- drivers/power/supply/bq27xxx_battery.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/power/supply/bq27xxx_battery.c b/drivers/power/supply/bq27xxx_battery.c index 45f0e39b8c2d..e72a9d839985 100644 --- a/drivers/power/supply/bq27xxx_battery.c +++ b/drivers/power/supply/bq27xxx_battery.c @@ -330,7 +330,7 @@ static u8 [BQ27XXX_REG_FLAGS] = 0x0a, [BQ27XXX_REG_TTE] = 0x16, [BQ27XXX_REG_TTF] = INVALID_REG_ADDR, - [BQ27XXX_REG_TTES] = 0x1c, + [BQ27XXX_REG_TTES] = 0x1a, [BQ27XXX_REG_TTECP] = INVALID_REG_ADDR, [BQ27XXX_REG_NAC] = 0x0c, [BQ27XXX_REG_RC] = 0x10,