net: dsa: microchip: ksz9477: split half-duplex monitoring function
In order to respect the 80 columns limit, split the half-duplex monitoring function in two. This is just a styling change, no functional change. Signed-off-by: Enguerrand de Ribaucourt <enguerrand.de-ribaucourt@savoirfairelinux.com> Acked-by: Arun Ramadoss <arun.ramadoss@microchip.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
462a94ec9f
commit
c4e82c025b
|
|
@ -427,54 +427,71 @@ void ksz9477_freeze_mib(struct ksz_device *dev, int port, bool freeze)
|
|||
mutex_unlock(&p->mib.cnt_mutex);
|
||||
}
|
||||
|
||||
static int ksz9477_half_duplex_monitor(struct ksz_device *dev, int port,
|
||||
u64 tx_late_col)
|
||||
{
|
||||
u8 lue_ctrl;
|
||||
u32 pmavbc;
|
||||
u16 pqm;
|
||||
int ret;
|
||||
|
||||
/* Errata DS80000754 recommends monitoring potential faults in
|
||||
* half-duplex mode. The switch might not be able to communicate anymore
|
||||
* in these states. If you see this message, please read the
|
||||
* errata-sheet for more information:
|
||||
* https://ww1.microchip.com/downloads/aemDocuments/documents
|
||||
* /UNG/ProductDocuments/Errata/KSZ9477S-Errata-DS80000754.pdf
|
||||
* To workaround this issue, half-duplex mode should be avoided.
|
||||
* A software reset could be implemented to recover from this state.
|
||||
*/
|
||||
dev_warn_once(dev->dev,
|
||||
"Half-duplex detected on port %d, transmission halt may occur\n",
|
||||
port);
|
||||
if (tx_late_col != 0) {
|
||||
/* Transmission halt with late collisions */
|
||||
dev_crit_once(dev->dev,
|
||||
"TX late collisions detected, transmission may be halted on port %d\n",
|
||||
port);
|
||||
}
|
||||
ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &lue_ctrl);
|
||||
if (ret)
|
||||
return ret;
|
||||
if (lue_ctrl & SW_VLAN_ENABLE) {
|
||||
ret = ksz_pread16(dev, port, REG_PORT_QM_TX_CNT_0__4, &pqm);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
ret = ksz_read32(dev, REG_PMAVBC, &pmavbc);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
if ((FIELD_GET(PMAVBC_MASK, pmavbc) <= PMAVBC_MIN) ||
|
||||
(FIELD_GET(PORT_QM_TX_CNT_M, pqm) >= PORT_QM_TX_CNT_MAX)) {
|
||||
/* Transmission halt with Half-Duplex and VLAN */
|
||||
dev_crit_once(dev->dev,
|
||||
"resources out of limits, transmission may be halted\n");
|
||||
}
|
||||
}
|
||||
|
||||
return ret;
|
||||
}
|
||||
|
||||
int ksz9477_errata_monitor(struct ksz_device *dev, int port,
|
||||
u64 tx_late_col)
|
||||
{
|
||||
u32 pmavbc;
|
||||
u8 status;
|
||||
u16 pqm;
|
||||
int ret;
|
||||
|
||||
ret = ksz_pread8(dev, port, REG_PORT_STATUS_0, &status);
|
||||
if (ret)
|
||||
return ret;
|
||||
if (!(FIELD_GET(PORT_INTF_SPEED_MASK, status) == PORT_INTF_SPEED_NONE) &&
|
||||
|
||||
if (!(FIELD_GET(PORT_INTF_SPEED_MASK, status)
|
||||
== PORT_INTF_SPEED_NONE) &&
|
||||
!(status & PORT_INTF_FULL_DUPLEX)) {
|
||||
/* Errata DS80000754 recommends monitoring potential faults in
|
||||
* half-duplex mode. The switch might not be able to communicate anymore
|
||||
* in these states.
|
||||
* If you see this message, please read the errata-sheet for more information:
|
||||
* https://ww1.microchip.com/downloads/aemDocuments/documents/UNG/ProductDocuments/Errata/KSZ9477S-Errata-DS80000754.pdf
|
||||
* To workaround this issue, half-duplex mode should be avoided.
|
||||
* A software reset could be implemented to recover from this state.
|
||||
*/
|
||||
dev_warn_once(dev->dev,
|
||||
"Half-duplex detected on port %d, transmission halt may occur\n",
|
||||
port);
|
||||
if (tx_late_col != 0) {
|
||||
/* Transmission halt with late collisions */
|
||||
dev_crit_once(dev->dev,
|
||||
"TX late collisions detected, transmission may be halted on port %d\n",
|
||||
port);
|
||||
}
|
||||
ret = ksz_read8(dev, REG_SW_LUE_CTRL_0, &status);
|
||||
if (ret)
|
||||
return ret;
|
||||
if (status & SW_VLAN_ENABLE) {
|
||||
ret = ksz_pread16(dev, port, REG_PORT_QM_TX_CNT_0__4, &pqm);
|
||||
if (ret)
|
||||
return ret;
|
||||
ret = ksz_read32(dev, REG_PMAVBC, &pmavbc);
|
||||
if (ret)
|
||||
return ret;
|
||||
if ((FIELD_GET(PMAVBC_MASK, pmavbc) <= PMAVBC_MIN) ||
|
||||
(FIELD_GET(PORT_QM_TX_CNT_M, pqm) >= PORT_QM_TX_CNT_MAX)) {
|
||||
/* Transmission halt with Half-Duplex and VLAN */
|
||||
dev_crit_once(dev->dev,
|
||||
"resources out of limits, transmission may be halted\n");
|
||||
}
|
||||
}
|
||||
ret = ksz9477_half_duplex_monitor(dev, port, tx_late_col);
|
||||
}
|
||||
|
||||
return ret;
|
||||
}
|
||||
|
||||
|
|
|
|||
Loading…