drm/xe/guc: Check error code when initializing the CT mutex

The initialization via drmm_mutex_init can fail, so we need to check the
return code and escalate the failure.

The mutex initialization has been moved after all the other init steps
that can't fail, so we're always guaranteed to have those done and don't
have to check in the cleanup code.

Signed-off-by: Daniele Ceraolo Spurio <daniele.ceraolospurio@intel.com>
Reviewed-by: Vinay Belgaumkar <vinay.belgaumkar@intel.com>
Link: https://patchwork.freedesktop.org/patch/msgid/20240321195512.274210-1-daniele.ceraolospurio@intel.com
This commit is contained in:
Daniele Ceraolo Spurio 2024-03-21 12:55:12 -07:00
parent c04b8aaeb4
commit b4abeb5545

View File

@ -145,13 +145,16 @@ int xe_guc_ct_init(struct xe_guc_ct *ct)
xe_assert(xe, !(guc_ct_size() % PAGE_SIZE));
drmm_mutex_init(&xe->drm, &ct->lock);
spin_lock_init(&ct->fast_lock);
xa_init(&ct->fence_lookup);
INIT_WORK(&ct->g2h_worker, g2h_worker_func);
init_waitqueue_head(&ct->wq);
init_waitqueue_head(&ct->g2h_fence_wq);
err = drmm_mutex_init(&xe->drm, &ct->lock);
if (err)
return err;
primelockdep(ct);
bo = xe_managed_bo_create_pin_map(xe, tile, guc_ct_size(),