ARM: dts: Cygnus: Fix SP805 clocks
The SP805 DT binding requires two clocks to be specified, but the Broadcom Cygnus DT currently only specifies one clock. In practice, Linux would pick a clock named "apb_pclk" for the bus clock, and the Linux and U-Boot SP805 driver would use the first clock to derive the actual watchdog counter frequency. Since currently both are the very same clock, we can just double the clock reference, and add the correct clock-names, to match the binding. Signed-off-by: Andre Przywara <andre.przywara@arm.com> Reviewed-by: Ray Jui <ray.jui@broadcom.com> Acked-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
This commit is contained in:
parent
5d00306e3a
commit
9d6693369f
|
|
@ -234,8 +234,8 @@ wdt0: wdt@18009000 {
|
|||
compatible = "arm,sp805" , "arm,primecell";
|
||||
reg = <0x18009000 0x1000>;
|
||||
interrupts = <GIC_SPI 91 IRQ_TYPE_LEVEL_HIGH>;
|
||||
clocks = <&axi81_clk>;
|
||||
clock-names = "apb_pclk";
|
||||
clocks = <&axi81_clk>, <&axi81_clk>;
|
||||
clock-names = "wdog_clk", "apb_pclk";
|
||||
};
|
||||
|
||||