ice: Fix VLAN pruning in switchdev mode
In switchdev mode the uplink VSI should receive all unmatched packets, including VLANs. Therefore, VLAN pruning should be disabled if uplink is in switchdev mode. It is already being done in ice_eswitch_setup_env(), however the addition of ice_up() in commit44ba608db5("ice: do switchdev slow-path Rx using PF VSI") caused VLAN pruning to be re-enabled after disabling it. Add a check to ice_set_vlan_filtering_features() to ensure VLAN filtering will not be enabled if uplink is in switchdev mode. Note that ice_is_eswitch_mode_switchdev() is being used instead of ice_is_switchdev_running(), as the latter would only return true after the whole switchdev setup completes. Fixes:44ba608db5("ice: do switchdev slow-path Rx using PF VSI") Reviewed-by: Michal Swiatkowski <michal.swiatkowski@linux.intel.com> Signed-off-by: Marcin Szycik <marcin.szycik@linux.intel.com> Tested-by: Priya Singh <priyax.singh@intel.com> Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
This commit is contained in:
parent
9ee87d2b21
commit
761e0be288
|
|
@ -6408,10 +6408,12 @@ ice_set_vlan_filtering_features(struct ice_vsi *vsi, netdev_features_t features)
|
|||
int err = 0;
|
||||
|
||||
/* support Single VLAN Mode (SVM) and Double VLAN Mode (DVM) by checking
|
||||
* if either bit is set
|
||||
* if either bit is set. In switchdev mode Rx filtering should never be
|
||||
* enabled.
|
||||
*/
|
||||
if (features &
|
||||
(NETIF_F_HW_VLAN_CTAG_FILTER | NETIF_F_HW_VLAN_STAG_FILTER))
|
||||
if ((features &
|
||||
(NETIF_F_HW_VLAN_CTAG_FILTER | NETIF_F_HW_VLAN_STAG_FILTER)) &&
|
||||
!ice_is_eswitch_mode_switchdev(vsi->back))
|
||||
err = vlan_ops->ena_rx_filtering(vsi);
|
||||
else
|
||||
err = vlan_ops->dis_rx_filtering(vsi);
|
||||
|
|
|
|||