mirror of
https://github.com/torvalds/linux.git
synced 2026-06-04 12:35:52 +02:00
docs: s390/pci: Improve and update PCI documentation
Update the s390 specific PCI documentation to better reflect current behavior and terms such as the handling of Isolated VFs via commit25f39d3dcb("s390/pci: Ignore RID for isolated VFs"). Add a descriptions for /sys/firmware/clp/uid_checking which was added in commitb043a81ce3("s390/pci: Expose firmware provided UID Checking state in sysfs") but missed documentation. Similarly add documentation for the fidparm attribute added by commit99ad39306a("s390/pci: Expose FIDPARM attribute in sysfs") and add a list of pft values and their names. Finally improve formatting of the different attribute descriptions by adding a separating colon. Reviewed-by: Farhan Ali <alifm@linux.ibm.com> Acked-by: Randy Dunlap <rdunlap@infradead.org> Tested-by: Randy Dunlap <rdunlap@infradead.org> Reviewed-by: Matthew Rosato <mjrosato@linux.ibm.com> Signed-off-by: Niklas Schnelle <schnelle@linux.ibm.com> Reviewed-by: Gerd Bayer <gbayer@linux.ibm.com> Link: https://lore.kernel.org/r/20260407-uid_slot-v8-1-15ae4409d2ce@linux.ibm.com Signed-off-by: Vasily Gorbik <gor@linux.ibm.com>
This commit is contained in:
parent
e3d074b5e6
commit
737c4f4a24
|
|
@ -6,6 +6,7 @@ S/390 PCI
|
|||
|
||||
Authors:
|
||||
- Pierre Morel
|
||||
- Niklas Schnelle
|
||||
|
||||
Copyright, IBM Corp. 2020
|
||||
|
||||
|
|
@ -27,14 +28,16 @@ Command line parameters
|
|||
debugfs entries
|
||||
---------------
|
||||
|
||||
The S/390 debug feature (s390dbf) generates views to hold various debug results in sysfs directories of the form:
|
||||
The S/390 debug feature (s390dbf) generates views to hold various debug results
|
||||
in sysfs directories of the form:
|
||||
|
||||
* /sys/kernel/debug/s390dbf/pci_*/
|
||||
|
||||
For example:
|
||||
|
||||
- /sys/kernel/debug/s390dbf/pci_msg/sprintf
|
||||
Holds messages from the processing of PCI events, like machine check handling
|
||||
|
||||
holds messages from the processing of PCI events, like machine check handling
|
||||
and setting of global functionality, like UID checking.
|
||||
|
||||
Change the level of logging to be more or less verbose by piping
|
||||
|
|
@ -47,87 +50,134 @@ Sysfs entries
|
|||
|
||||
Entries specific to zPCI functions and entries that hold zPCI information.
|
||||
|
||||
* /sys/bus/pci/slots/XXXXXXXX
|
||||
* /sys/bus/pci/slots/XXXXXXXX:
|
||||
|
||||
The slot entries are set up using the function identifier (FID) of the
|
||||
PCI function. The format depicted as XXXXXXXX above is 8 hexadecimal digits
|
||||
with 0 padding and lower case hexadecimal digits.
|
||||
The slot entries are set up using the function identifier (FID) of the PCI
|
||||
function as slot name. The format depicted as XXXXXXXX above is 8 hexadecimal
|
||||
digits with 0 padding and lower case hexadecimal digits.
|
||||
|
||||
- /sys/bus/pci/slots/XXXXXXXX/power
|
||||
|
||||
A physical function that currently supports a virtual function cannot be
|
||||
powered off until all virtual functions are removed with:
|
||||
echo 0 > /sys/bus/pci/devices/XXXX:XX:XX.X/sriov_numvf
|
||||
echo 0 > /sys/bus/pci/devices/DDDD:BB:dd.f/sriov_numvf
|
||||
|
||||
* /sys/bus/pci/devices/XXXX:XX:XX.X/
|
||||
* /sys/bus/pci/devices/DDDD:BB:dd.f/:
|
||||
|
||||
- function_id
|
||||
A zPCI function identifier that uniquely identifies the function in the Z server.
|
||||
- function_id:
|
||||
The zPCI function identifier (FID) is a 32-bit hexadecimal value that
|
||||
uniquely identifies the PCI function. Unless the hypervisor provides
|
||||
a virtual FID e.g. on KVM this identifier is unique across the machine even
|
||||
between different partitions.
|
||||
|
||||
- function_handle
|
||||
Low-level identifier used for a configured PCI function.
|
||||
It might be useful for debugging.
|
||||
- function_handle:
|
||||
This 32-bit hexadecimal value is a low-level identifier used for a PCI
|
||||
function. Note that the function handle may be changed and become invalid
|
||||
on PCI events and when enabling/disabling the PCI function.
|
||||
|
||||
- pchid
|
||||
Model-dependent location of the I/O adapter.
|
||||
- pchid:
|
||||
This 16-bit hexadecimal value encodes a model-dependent location for
|
||||
the PCI function.
|
||||
|
||||
- pfgid
|
||||
PCI function group ID, functions that share identical functionality
|
||||
- pfgid:
|
||||
PCI function group ID; functions that share identical functionality
|
||||
use a common identifier.
|
||||
A PCI group defines interrupts, IOMMU, IOTLB, and DMA specifics.
|
||||
|
||||
- vfn
|
||||
- vfn:
|
||||
The virtual function number, from 1 to N for virtual functions,
|
||||
0 for physical functions.
|
||||
|
||||
- pft
|
||||
The PCI function type
|
||||
- pft:
|
||||
The PCI function type is an s390-specific type attribute. It indicates
|
||||
a more general, usage oriented, type than PCI Specification
|
||||
class/vendor/device identifiers. That is PCI functions with the same pft
|
||||
value may be backed by different hardware implementations. At the same time
|
||||
apart from unclassified functions (pft is 0x00) the same pft value
|
||||
generally implies a similar usage model. At the same time the same
|
||||
PCI hardware device may appear with different pft values when in a
|
||||
different usage model. For example NETD and NETH VFs may be implemented
|
||||
by the same PCI hardware device but in NETD the parent Physical Function
|
||||
is user managed while with NETH it is platform managed.
|
||||
|
||||
- port
|
||||
The port corresponds to the physical port the function is attached to.
|
||||
It also gives an indication of the physical function a virtual function
|
||||
is attached to.
|
||||
Currently the following PFT values are defined:
|
||||
|
||||
- uid
|
||||
The user identifier (UID) may be defined as part of the machine
|
||||
configuration or the z/VM or KVM guest configuration. If the accompanying
|
||||
uid_is_unique attribute is 1 the platform guarantees that the UID is unique
|
||||
within that instance and no devices with the same UID can be attached
|
||||
during the lifetime of the system.
|
||||
- 0x00 (UNC): Unclassified
|
||||
- 0x02 (ROCE): RoCE Express
|
||||
- 0x05 (ISM): Internal Shared Memory
|
||||
- 0x0a (ROC2): RoCE Express 2
|
||||
- 0x0b (NVMe): NVMe
|
||||
- 0x0c (NETH): Network Express hybrid
|
||||
- 0x0d (CNW): Cloud Network Adapter
|
||||
- 0x0f (NETD): Network Express direct
|
||||
|
||||
- uid_is_unique
|
||||
Indicates whether the user identifier (UID) is guaranteed to be and remain
|
||||
unique within this Linux instance.
|
||||
- port:
|
||||
The port is a decimal value corresponding to the physical port the function
|
||||
is attached to. Virtual Functions (VFs) share the port with their parent
|
||||
Physical Function (PF). A value of 0 indicates that the port attribute is
|
||||
not applicable for that PCI function type.
|
||||
|
||||
- pfip/segmentX
|
||||
- uid:
|
||||
The user-defined identifier (UID) for a PCI function is a 32-bit
|
||||
hexadecimal value. It is defined on a per instance basis as part of the
|
||||
partition, KVM guest, or z/VM guest configuration. If UID Checking is
|
||||
enabled the platform ensures that the UID is unique within that instance
|
||||
and no two PCI functions with the same UID will be visible to the instance.
|
||||
|
||||
Independent of this guarantee and unlike the function ID (FID) the UID may
|
||||
be the same in different partitions within the same machine. This allows to
|
||||
create PCI configurations in multiple partitions to be identical in the
|
||||
UID-namespace.
|
||||
|
||||
- uid_is_unique:
|
||||
A 0 or 1 flag indicating whether the user-defined identifier (UID) is
|
||||
guaranteed to be and remain unique within this Linux instance. This
|
||||
platform feature is called UID Checking.
|
||||
|
||||
- pfip/segmentX:
|
||||
The segments determine the isolation of a function.
|
||||
They correspond to the physical path to the function.
|
||||
The more the segments are different, the more the functions are isolated.
|
||||
|
||||
- fidparm:
|
||||
Contains an 8-bit-per-PCI function parameter field in hexadecimal provided
|
||||
by the platform. The meaning of this field is PCI function type specific.
|
||||
For NETH VFs a value of 0x01 indicates that the function supports
|
||||
promiscuous mode.
|
||||
|
||||
* /sys/firmware/clp/uid_checking:
|
||||
|
||||
In addition to the per-device uid_is_unique attribute this presents a
|
||||
global indication of whether UID Checking is enabled. This allows users
|
||||
to check for UID Checking even when no PCI functions are configured.
|
||||
|
||||
Enumeration and hotplug
|
||||
=======================
|
||||
|
||||
The PCI address consists of four parts: domain, bus, device and function,
|
||||
and is of this form: DDDD:BB:dd.f
|
||||
and is of this form: DDDD:BB:dd.f.
|
||||
|
||||
* When not using multi-functions (norid is set, or the firmware does not
|
||||
support multi-functions):
|
||||
* For a PCI function for which the platform does not expose the RID, the
|
||||
pci=norid kernel parameter is used, or a so-called isolated Virtual Function
|
||||
which does have RID information but is used without its parent Physical
|
||||
Function being part of the same PCI configuration:
|
||||
|
||||
- There is only one function per domain.
|
||||
|
||||
- The domain is set from the zPCI function's UID as defined during the
|
||||
LPAR creation.
|
||||
- The domain is set from the zPCI function's UID if UID Checking is on;
|
||||
otherwise the domain ID is generated dynamically and is not stable
|
||||
across reboots or hot plug.
|
||||
|
||||
* When using multi-functions (norid parameter is not set),
|
||||
zPCI functions are addressed differently:
|
||||
* For a PCI function for which the platform exposes the RID and which
|
||||
is not an Isolated Virtual Function:
|
||||
|
||||
- There is still only one bus per domain.
|
||||
|
||||
- There can be up to 256 functions per bus.
|
||||
- There can be up to 256 PCI functions per bus.
|
||||
|
||||
- The domain part of the address of all functions for
|
||||
a multi-Function device is set from the zPCI function's UID as defined
|
||||
in the LPAR creation for the function zero.
|
||||
- The domain part of the address of all functions within the same topology is
|
||||
that of the configured PCI function with the lowest devfn within that
|
||||
topology.
|
||||
|
||||
- New functions will only be ready for use after the function zero
|
||||
(the function with devfn 0) has been enumerated.
|
||||
- Virtual Functions generated by an SR-IOV capable Physical Function only
|
||||
become visible once SR-IOV is enabled.
|
||||
|
|
|
|||
Loading…
Reference in New Issue