staging: greybus: uart: check return values during probe

Check the return values of send_control() and send_line_coding() during
device initialization in gb_uart_probe(). If these operations fail, the
device will be left in an inconsistent state, so propagate the error to
properly fail the probe.

Both functions call gb_operation_sync() which can fail with errors such
as -ENOMEM, -ENODEV, or -ETIMEDOUT. Ignoring these errors means the TTY
device would be registered despite incomplete initialization.

Signed-off-by: Nirbhay Sharma <nirbhay.lkd@gmail.com>
Link: https://patch.msgid.link/20251115061646.160847-2-nirbhay.lkd@gmail.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Nirbhay Sharma 2025-11-15 11:46:47 +05:30 committed by Greg Kroah-Hartman
parent 47d3949a9b
commit 706cc5a936

View File

@ -879,14 +879,18 @@ static int gb_uart_probe(struct gbphy_device *gbphy_dev,
if (retval)
goto exit_put_port;
send_control(gb_tty, gb_tty->ctrlout);
retval = send_control(gb_tty, gb_tty->ctrlout);
if (retval)
goto exit_connection_disable;
/* initialize the uart to be 9600n81 */
gb_tty->line_coding.rate = cpu_to_le32(9600);
gb_tty->line_coding.format = GB_SERIAL_1_STOP_BITS;
gb_tty->line_coding.parity = GB_SERIAL_NO_PARITY;
gb_tty->line_coding.data_bits = 8;
send_line_coding(gb_tty);
retval = send_line_coding(gb_tty);
if (retval)
goto exit_connection_disable;
retval = gb_connection_enable(connection);
if (retval)