dt-bindings: thermal: cooling-devices: Update support for 3 cells cooling device
Extend the thermal cooling device binding to support a 3 cells specifier along with the 2 cells format. Update #cooling-cells property to enum to support both 2 and 3 arguments. Fix pwm-fan.yaml to restrict the number of cells to 'const: 2' Signed-off-by: Gaurav Kohli <gaurav.kohli@oss.qualcomm.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@oss.qualcomm.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@kernel.org> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@oss.qualcomm.com> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Acked-by: Rafael J. Wysocki (Intel) <rafael@kernel.org> Link: https://patch.msgid.link/20260526140802.1059293-22-daniel.lezcano@oss.qualcomm.com
This commit is contained in:
parent
2baee1cc03
commit
6d0c207c0a
|
|
@ -63,7 +63,8 @@ properties:
|
|||
description: The PWM that is used to control the fan.
|
||||
maxItems: 1
|
||||
|
||||
"#cooling-cells": true
|
||||
"#cooling-cells":
|
||||
const: 2
|
||||
|
||||
required:
|
||||
- compatible
|
||||
|
|
|
|||
|
|
@ -44,10 +44,14 @@ select: true
|
|||
properties:
|
||||
"#cooling-cells":
|
||||
description:
|
||||
Must be 2, in order to specify minimum and maximum cooling state used in
|
||||
Must be 2 or 3. If 2, specifies minimum and maximum cooling state used in
|
||||
the cooling-maps reference. The first cell is the minimum cooling state
|
||||
and the second cell is the maximum cooling state requested.
|
||||
const: 2
|
||||
If 3, the first cell specifies the thermal mitigation device specifier
|
||||
index for devices that support multiple thermal mitigation mechanisms.
|
||||
The two other cells are respectively the minimum cooling state and the
|
||||
maximum cooling state.
|
||||
enum: [2, 3]
|
||||
|
||||
additionalProperties: true
|
||||
|
||||
|
|
|
|||
|
|
@ -211,7 +211,8 @@ patternProperties:
|
|||
device. Using the THERMAL_NO_LIMIT (-1UL) constant in the
|
||||
cooling-device phandle limit specifier lets the framework
|
||||
use the minimum and maximum cooling state for that cooling
|
||||
device automatically.
|
||||
device automatically. If three arguments are specified,
|
||||
the first argument is the cooling device specifier.
|
||||
|
||||
contribution:
|
||||
$ref: /schemas/types.yaml#/definitions/uint32
|
||||
|
|
|
|||