mirror of
https://github.com/torvalds/linux.git
synced 2026-06-09 23:23:53 +02:00
drm/i915: prefer wide & slow to fast & narrow in DP configs
commit 2514bc510d upstream.
High frequency link configurations have the potential to cause trouble
with long and/or cheap cables, so prefer slow and wide configurations
instead. This patch has the potential to cause trouble for eDP
configurations that lie about available lanes, so if we run into that we
can make it conditional on eDP.
Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=45801
Tested-by: peter@colberg.org
Signed-off-by: Jesse Barnes <jbarnes@virtuousgeek.org>
Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Cc: Jonathan Nieder <jrnieder@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
b9247be526
commit
6700eb4d0a
|
|
@ -712,8 +712,8 @@ intel_dp_mode_fixup(struct drm_encoder *encoder, struct drm_display_mode *mode,
|
|||
|
||||
bpp = adjusted_mode->private_flags & INTEL_MODE_DP_FORCE_6BPC ? 18 : 24;
|
||||
|
||||
for (lane_count = 1; lane_count <= max_lane_count; lane_count <<= 1) {
|
||||
for (clock = 0; clock <= max_clock; clock++) {
|
||||
for (clock = 0; clock <= max_clock; clock++) {
|
||||
for (lane_count = 1; lane_count <= max_lane_count; lane_count <<= 1) {
|
||||
int link_avail = intel_dp_max_data_rate(intel_dp_link_clock(bws[clock]), lane_count);
|
||||
|
||||
if (intel_dp_link_required(mode->clock, bpp)
|
||||
|
|
|
|||