power: supply: qcom_battmgr: Report battery capacity

Battery charge can be reported in several different ways. One of them is
is charge percentage referred to as POWER_SUPPLY_PROP_CAPACITY in the
power supply API. Currently the driver reports the capacity in this way
on SM8350, but not on the newer variants referred to as SC8280XP in the
driver. Although this is not a bug in itself, not reporting the
percentage can confuse some userspace consumers.
Mimic what is done in the ACPI driver (drivers/acpi/battery.c) and
calculate the percentage capacity by dividing the current charge value
by the full charge.

Signed-off-by: Kornel Dulęba <korneld@google.com>
Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@oss.qualcomm.com>
Link: https://lore.kernel.org/r/20250528112328.1640743-2-korneld@google.com
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Kornel Dulęba 2025-05-28 11:23:29 +00:00 committed by Sebastian Reichel
parent 6aa1c3a72b
commit 3f87baacea

View File

@ -577,6 +577,8 @@ static int qcom_battmgr_bat_get_property(struct power_supply *psy,
val->intval = battmgr->status.capacity;
break;
case POWER_SUPPLY_PROP_CAPACITY:
if (battmgr->status.percent == (unsigned int)-1)
return -ENODATA;
val->intval = battmgr->status.percent;
break;
case POWER_SUPPLY_PROP_TEMP:
@ -617,6 +619,7 @@ static const enum power_supply_property sc8280xp_bat_props[] = {
POWER_SUPPLY_PROP_STATUS,
POWER_SUPPLY_PROP_PRESENT,
POWER_SUPPLY_PROP_TECHNOLOGY,
POWER_SUPPLY_PROP_CAPACITY,
POWER_SUPPLY_PROP_CYCLE_COUNT,
POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
POWER_SUPPLY_PROP_VOLTAGE_NOW,
@ -1063,6 +1066,26 @@ static void qcom_battmgr_sc8280xp_callback(struct qcom_battmgr *battmgr,
battmgr->ac.online = source == BATTMGR_CHARGING_SOURCE_AC;
battmgr->usb.online = source == BATTMGR_CHARGING_SOURCE_USB;
battmgr->wireless.online = source == BATTMGR_CHARGING_SOURCE_WIRELESS;
if (battmgr->info.last_full_capacity != 0) {
/*
* 100 * battmgr->status.capacity can overflow a 32bit
* unsigned integer. FW readings are in m{W/A}h, which
* are multiplied by 1000 converting them to u{W/A}h,
* the format the power_supply API expects.
* To avoid overflow use the original value for dividend
* and convert the divider back to m{W/A}h, which can be
* done without any loss of precision.
*/
battmgr->status.percent =
(100 * le32_to_cpu(resp->status.capacity)) /
(battmgr->info.last_full_capacity / 1000);
} else {
/*
* Let the sysfs handler know no data is available at
* this time.
*/
battmgr->status.percent = (unsigned int)-1;
}
break;
case BATTMGR_BAT_DISCHARGE_TIME:
battmgr->status.discharge_time = le32_to_cpu(resp->time);