mt76: fix wrong HE data rate in sniffer tool

Due to the missing IEEE80211_RADIOTAP_HE_DATA1_BW_RU_ALLOC_KNOWN in
status report, the HE rate in wirehsark/tcpdump always shows wrong value.
Applications will refer to IEEE80211_RADIOTAP_HE_DATA5_DATA_BW_RU_ALLOC
when the flag is set and shows the correct data rate.

Reviewed-by: Ryder Lee <ryder.lee@mediatek.com>
Signed-off-by: Deren Wu <deren.wu@mediatek.com>
Signed-off-by: Felix Fietkau <nbd@nbd.name>
This commit is contained in:
Deren Wu 2022-03-16 00:24:34 +08:00 committed by Felix Fietkau
parent 6b7f9aff7c
commit 32bfd77462
2 changed files with 8 additions and 4 deletions

View File

@ -349,14 +349,16 @@ mt7915_mac_decode_he_radiotap(struct sk_buff *skb, __le32 *rxv, u32 mode)
case MT_PHY_TYPE_HE_SU:
he->data1 |= HE_BITS(DATA1_FORMAT_SU) |
HE_BITS(DATA1_UL_DL_KNOWN) |
HE_BITS(DATA1_BEAM_CHANGE_KNOWN);
HE_BITS(DATA1_BEAM_CHANGE_KNOWN) |
HE_BITS(DATA1_BW_RU_ALLOC_KNOWN);
he->data3 |= HE_PREP(DATA3_BEAM_CHANGE, BEAM_CHNG, rxv[14]) |
HE_PREP(DATA3_UL_DL, UPLINK, rxv[2]);
break;
case MT_PHY_TYPE_HE_EXT_SU:
he->data1 |= HE_BITS(DATA1_FORMAT_EXT_SU) |
HE_BITS(DATA1_UL_DL_KNOWN);
HE_BITS(DATA1_UL_DL_KNOWN) |
HE_BITS(DATA1_BW_RU_ALLOC_KNOWN);
he->data3 |= HE_PREP(DATA3_UL_DL, UPLINK, rxv[2]);
break;

View File

@ -304,14 +304,16 @@ mt7921_mac_decode_he_radiotap(struct sk_buff *skb, __le32 *rxv, u32 mode)
case MT_PHY_TYPE_HE_SU:
he->data1 |= HE_BITS(DATA1_FORMAT_SU) |
HE_BITS(DATA1_UL_DL_KNOWN) |
HE_BITS(DATA1_BEAM_CHANGE_KNOWN);
HE_BITS(DATA1_BEAM_CHANGE_KNOWN) |
HE_BITS(DATA1_BW_RU_ALLOC_KNOWN);
he->data3 |= HE_PREP(DATA3_BEAM_CHANGE, BEAM_CHNG, rxv[14]) |
HE_PREP(DATA3_UL_DL, UPLINK, rxv[2]);
break;
case MT_PHY_TYPE_HE_EXT_SU:
he->data1 |= HE_BITS(DATA1_FORMAT_EXT_SU) |
HE_BITS(DATA1_UL_DL_KNOWN);
HE_BITS(DATA1_UL_DL_KNOWN) |
HE_BITS(DATA1_BW_RU_ALLOC_KNOWN);
he->data3 |= HE_PREP(DATA3_UL_DL, UPLINK, rxv[2]);
break;