drm/radeon/kms: Fix logic error in DP HPD handler

commit 5ba7ddf816 upstream.

Only disable the pipe if the monitor is physically
disconnected.  The previous logic also disabled the
pipe if the link was trained.

Fixes:
https://bugs.freedesktop.org/show_bug.cgi?id=41248

Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
Signed-off-by: Dave Airlie <airlied@redhat.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:
Alex Deucher 2011-10-03 08:37:33 -04:00 committed by Greg Kroah-Hartman
parent 1a795f752c
commit 23882c85d9

View File

@ -68,11 +68,11 @@ void radeon_connector_hotplug(struct drm_connector *connector)
if (connector->connector_type == DRM_MODE_CONNECTOR_DisplayPort) {
int saved_dpms = connector->dpms;
if (radeon_hpd_sense(rdev, radeon_connector->hpd.hpd) &&
radeon_dp_needs_link_train(radeon_connector))
drm_helper_connector_dpms(connector, DRM_MODE_DPMS_ON);
else
/* Only turn off the display it it's physically disconnected */
if (!radeon_hpd_sense(rdev, radeon_connector->hpd.hpd))
drm_helper_connector_dpms(connector, DRM_MODE_DPMS_OFF);
else if (radeon_dp_needs_link_train(radeon_connector))
drm_helper_connector_dpms(connector, DRM_MODE_DPMS_ON);
connector->dpms = saved_dpms;
}
}