cifs: Show reason why autodisabling serverino support

Extend cifs_autodisable_serverino() function to print also text message why
the function was called.

The text message is printed just once for mount then autodisabling
serverino support. Once the serverino support is disabled for mount it will
not be re-enabled. So those text messages do not cause flooding logs.

This change allows to debug issues why cifs.ko decide to turn off server
inode number support and hence disable support for detection of hardlinks.

Signed-off-by: Pali Rohár <pali@kernel.org>
Signed-off-by: Steve French <stfrench@microsoft.com>
This commit is contained in:
Pali Rohár 2026-07-06 20:29:36 +02:00 committed by Steve French
parent 9dd1964ac5
commit 179e3ee985
6 changed files with 14 additions and 9 deletions

View File

@ -317,7 +317,7 @@ int generate_smb311signingkey(struct cifs_ses *ses,
#ifdef CONFIG_CIFS_ALLOW_INSECURE_LEGACY
#endif /* CONFIG_CIFS_ALLOW_INSECURE_LEGACY */
void cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb);
void cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb, const char *reason, int rc);
bool couldbe_mf_symlink(const struct cifs_fattr *fattr);
int check_mf_symlink(unsigned int xid, struct cifs_tcon *tcon,
struct cifs_sb_info *cifs_sb, struct cifs_fattr *fattr,

View File

@ -3876,7 +3876,7 @@ int cifs_mount(struct cifs_sb_info *cifs_sb, struct smb3_fs_context *ctx)
* After reconnecting to a different server, unique ids won't match anymore, so we disable
* serverino. This prevents dentry revalidation to think the dentry are stale (ESTALE).
*/
cifs_autodisable_serverino(cifs_sb);
cifs_autodisable_serverino(cifs_sb, "DFS failover may potentially connect to a different server, inode numbers won't match anymore", 0);
/*
* Force the use of prefix path to support failover on DFS paths that resolve to targets
* that have different prefix paths.

View File

@ -1328,7 +1328,7 @@ int dfs_cache_remount_fs(struct cifs_sb_info *cifs_sb)
* After reconnecting to a different server, unique ids won't match anymore, so we disable
* serverino. This prevents dentry revalidation to think the dentry are stale (ESTALE).
*/
cifs_autodisable_serverino(cifs_sb);
cifs_autodisable_serverino(cifs_sb, "DFS failover may potentially connect to a different server, inode numbers won't match anymore", 0);
/*
* Force the use of prefix path to support failover on DFS paths that resolve to targets
* that have different prefix paths.

View File

@ -1147,7 +1147,7 @@ static void cifs_set_fattr_ino(int xid, struct cifs_tcon *tcon, struct super_blo
fattr->cf_uniqueid = CIFS_I(*inode)->uniqueid;
else {
fattr->cf_uniqueid = iunique(sb, ROOT_I);
cifs_autodisable_serverino(cifs_sb);
cifs_autodisable_serverino(cifs_sb, "Cannot retrieve inode number via get_srv_inum", rc);
}
return;
}
@ -1644,7 +1644,7 @@ cifs_iget(struct super_block *sb, struct cifs_fattr *fattr)
fattr->cf_flags &= ~CIFS_FATTR_INO_COLLISION;
if (inode_has_hashed_dentries(inode)) {
cifs_autodisable_serverino(CIFS_SB(sb));
cifs_autodisable_serverino(CIFS_SB(sb), "Inode number collision detected", 0);
iput(inode);
fattr->cf_uniqueid = iunique(sb, ROOT_I);
goto retry_iget5_locked;
@ -1710,8 +1710,9 @@ struct inode *cifs_root_iget(struct super_block *sb)
iget_root:
if (!rc) {
if (fattr.cf_flags & CIFS_FATTR_JUNCTION) {
cifs_dbg(VFS, "Removing junction mark and disabling 'serverino' to prevent inode collisions\n");
fattr.cf_flags &= ~CIFS_FATTR_JUNCTION;
cifs_autodisable_serverino(cifs_sb);
cifs_autodisable_serverino(cifs_sb, "Cannot retrieve attributes for junction point", rc);
}
inode = cifs_iget(sb, &fattr);
}

View File

@ -278,7 +278,7 @@ dump_smb(void *buf, int smb_buf_length)
}
void
cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb)
cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb, const char *reason, int rc)
{
unsigned int sbflags = cifs_sb_flags(cifs_sb);
@ -290,6 +290,10 @@ cifs_autodisable_serverino(struct cifs_sb_info *cifs_sb)
atomic_andnot(CIFS_MOUNT_SERVER_INUM, &cifs_sb->mnt_cifs_flags);
cifs_sb->mnt_cifs_serverino_autodisabled = true;
if (rc)
cifs_dbg(VFS, "%s: %d\n", reason, rc);
else
cifs_dbg(VFS, "%s\n", reason);
cifs_dbg(VFS, "Autodisabling the use of server inode numbers on %s\n",
tcon ? tcon->tree_name : "new server");
cifs_dbg(VFS, "The server doesn't seem to support them properly or the files might be on different servers (DFS)\n");

View File

@ -415,7 +415,7 @@ _initiate_cifs_search(const unsigned int xid, struct file *file,
if (rc == 0) {
cifsFile->invalidHandle = false;
} else if (rc == -EOPNOTSUPP && (sbflags & CIFS_MOUNT_SERVER_INUM)) {
cifs_autodisable_serverino(cifs_sb);
cifs_autodisable_serverino(cifs_sb, "Cannot retrieve inode number via query_dir_first", rc);
goto ffirst_retry;
}
error_exit:
@ -1029,7 +1029,7 @@ static int cifs_filldir(char *find_entry, struct file *file,
fattr.cf_uniqueid = de.ino;
} else {
fattr.cf_uniqueid = iunique(sb, ROOT_I);
cifs_autodisable_serverino(cifs_sb);
cifs_autodisable_serverino(cifs_sb, "Cannot retrieve inode number from readdir", 0);
}
if ((sbflags & CIFS_MOUNT_MF_SYMLINKS) && couldbe_mf_symlink(&fattr))