power: supply: bq25890: fix the -10 C NTC lookup entry
The TSPCT lookup table is monotonically decreasing except for ADC code
121, where the sequence reads -9.0 C, -1.0 C, -12.0 C. This makes the
reported battery temperature jump upward by eight degrees for one code
and then downward by eleven degrees for the next code.
The entry is a missing zero: use -10.0 C so the sequence remains
monotonic between -9.0 C and -12.0 C.
Fixes: 9652c02428 ("power: bq25890: add POWER_SUPPLY_PROP_TEMP")
Cc: stable@vger.kernel.org
Signed-off-by: Xu Rao <raoxu@uniontech.com>
Link: https://patch.msgid.link/0619C8BF15F43B7C+20260723065444.1796002-1-raoxu@uniontech.com
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
f7b253a6e2
commit
160a783aa6
|
|
@ -320,7 +320,7 @@ static const u32 bq25890_tspct_tbl[] = {
|
|||
145, 140, 130, 120, 115, 110, 100, 90,
|
||||
80, 70, 60, 50, 40, 30, 20, 10,
|
||||
0, -10, -20, -30, -40, -60, -70, -80,
|
||||
-90, -10, -120, -140, -150, -170, -190, -210,
|
||||
-90, -100, -120, -140, -150, -170, -190, -210,
|
||||
};
|
||||
|
||||
#define BQ25890_TSPCT_TBL_SIZE ARRAY_SIZE(bq25890_tspct_tbl)
|
||||
|
|
|
|||